Forced Entry & Ballistic Resistant Louvers
Reinforced louver assemblies engineered to protect ventilation openings against forced entry while maintaining required airflow. Habersham’s FEBR louvers are built for secure facility applications where exterior openings need added resistance without eliminating functional ventilation.
Protects Ventilation Openings
Forced-Entry Resistance
Built for applications requiring extended resistance against sustained forced-entry attempts.
Ballistic Protection
Built and tested for specific for bullet penetration resistance
Reinforced Plate Construction
Designed with reinforced louver plate construction for demanding security applications.
Application-Specific Fit
Configured around opening size, embed conditions, ventilation needs, and facility requirements.
Forced Entry Tested
Ballistic Resistant Tested
ASTM
U.S Department of State
UL 752 / SD-STD-01.01
FEBR Louver Assembly Details
Overview (General Description)
Habersham’s FEBR louver assemblies are engineered to secure ventilation openings without eliminating required airflow. Built with reinforced louver plate construction and embed installation conditions, these assemblies help protect vulnerable exterior or interior air-transfer points in high security facilities.
Product Details:
- 60-Minute FEBR Design: Built for applications requiring extended forced entry resistance at ventilation openings.
- Reinforced Louver Plate: Security focused plate construction helps resist physical attack while supporting airflow needs.
- Embed Installation: Designed for embedded installation conditions to strengthen the connection between the louver assembly and surrounding wall system.
- Ventilation + Protection: Supports functional airflow while helping reduce the vulnerability of exposed louver openings.
- Fire-Rated Options: Fire ratings of up to 3 hours are available in accordance with the referenced standards listed on the tech sheet.
- Project-Specific Configuration: Configured around opening size, wall condition, ventilation needs, and required security performance.
- Confident Protection: We conduct in-house testing and product development to enhance Habersham’s management approach, manufacturing processes, and product designs. You can be confident that your protection will always be our primary focus.
Performance Snapshot
Built to protect ventilation openings while maintaining functional airflow.
- 60-minute FEBR louver assembly
- Forced-entry resistant design
- Reinforced louver plate construction
- Built for exterior or interior openings
- Designed for high-security facility applications
- Project-specific sizing and installation conditions
FEBR Louvers in Real World Applications
Engineered opening protection for facilities where forced entry resistance, ballistic performance, and long term durability are mission critical.